Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
1.
Acta Academiae Medicinae Sinicae ; (6): 696-701, 2016.
Article in English | WPRIM | ID: wpr-277919

ABSTRACT

Objective To explore the expressions of inhibitors of DNA binding-1 (Id-1) and matrix metalloproteinase-9 (MMP-9) in colorectal carcinoma tissues and its correlation with microvessel density (MVD). Methods The expressions of Id-1 and MMP-9 as well as CD34-labelled MVD in colorectal adenocarcinoma tissues (n=50) and normal adjacent tissues (n=50) were examined by immunohistochemistry. Results The positive expressions of Id-1 and MMP-9 were seen in 72.00% (36/50) and 78.00%(39/50) of colorectal adenocarcinoma tissues,which were significantly higher than those [24.00%(12/50) and 28.00% (14/50)] in normal adjacent tissues (P=0.000). The MVD value (17.22±2.08) in colorectal adenocarcinoma tissues was significantly higher than that (5.36±2.17) in normal adjacent tissues (P=0.000). The expressions of Id-1 and MMP-9 and MVD were significantly correlated with serosa invasion,TNM stage,carcinoembryonic antigen(+),lymph node metastasis,vascular invasion,and liver metastasis (all P<0.05) but not with the patient's age,gender,tumor size,and differentiation degree (all P>0.05). The MVD value with Id-1 and MMP-9 positive expression were significantly higher than those with Id-1 and MMP-9 negative expression (all P=0.000). The expression of Id-1 in colorectal adenocarcinoma tissues showed significantly positive correlation with that of MMP-9 (r=0.429,P=0.000). Cox multivariate analysis showed that Id-1 and MMP-9 expressions were independent prognostic factors for colorectal carcinoma. Conclusions The high expressions of Id-1 and MMP-9 have high correlations with the development and progression of colorectal adenocarcinoma and have positive correlation with MVD. Both of them may be involved in the microvascular generation and the invasion and hematogenous metastasis of colorectal carcinoma.


Subject(s)
Humans , Adenocarcinoma , Metabolism , Colorectal Neoplasms , Metabolism , Disease Progression , Immunohistochemistry , Inhibitor of Differentiation Protein 1 , Metabolism , Liver Neoplasms , Lymphatic Metastasis , Matrix Metalloproteinase 9 , Metabolism , Microcirculation , Microvessels , Neovascularization, Pathologic
2.
Chinese Journal of Radiology ; (12)2001.
Article in Chinese | WPRIM | ID: wpr-680030

ABSTRACT

Objective To describe a new kind of Y-shaped metallic stent delivery system and evaluate its feasibility and preliminary effect for managing multiple airway stenoses involving the lower trachea and the tracheal carina.Methods The Y-shaped metallic stent delivery system consisted of three- tier structure.The inner-tier was composed of four parallel guiding tubes,which was used for two guidewires and two threads passing through,the middle-tier was delivery catheter,which contained the four guiding tubes,and the outer-tier was introducer sheath.Under the fluoroscopic guidance,15 patients with multiple stenoses involving the lower trachea and the tracheal carina were treated with the new covered self-expandable Y-shaped metallic stents.Results Stent placement in the tracheo-bronchial tree was technically successful in all patients with obliteration of the dyspnea immediately after stent placement,and SaO_2 was increased form preoperative 75%—89% to postoperative 96%—99%.During follow-up a period of 3—58 weeks (M 22 weeks),all stenosis were resolved without stent-related complications,and the general physical of all 15 patents was improved with no occurrence of obviously dyspnea and bleeding.Karnofsky performance status(KPS)was improved from preoperative 26%—45% to postoperative 72%—95%.Five patients died of the following causes unrelated to stent insertion:multiple organ failure(n=3),cachexia(n=1)and pulmonary infection caused by gastrobronchial fistula(n=1),and the remaining 10 patients were alive with no evidence.of dyspnea at the time of this report.Conclusion Deployment of the covered Y-shaped metallic stent with the use of Y metallic stent delivery system in the management of airway stenoses involving the lower trachea and the tracheal earina was a simple and safe procedure and with a good short-term clinical efficacy.

3.
Journal of Interventional Radiology ; (12)1994.
Article in Chinese | WPRIM | ID: wpr-682992

ABSTRACT

Objective To investigate the feasibility and primary therapeutic effect of inverted Y-shaped self-expandable metal stent for complex airway stenosis.Methods On the standpoint of the peculiar anatomic structure and the pathological changes of complex airway stenosis,we designed the inverted Y-shaped self- expandable metal stent.Under the fluoroscopic guidance,7 stents were implanted in 7 cases of airway complex stenosis.Results The inverted Y-shaped self-expandable metal stents were placed seccussfully,with instantaneous relief of dyspnea and improvement of living quality.Conclusion The placement of inverted Y- shaped self-expandable metal stent is feasible and safe for treating airway complex stenosis.(J Intervent Radiol, 2007,16:92-94)

SELECTION OF CITATIONS
SEARCH DETAIL